For flattening the alveolar crest or harvesting bone fragments.
• POWER LEVEL [SURG] 80%
• TiN coating
• Triple sided edge spatula tip
• Single-edged scraper
				
	For flattening the alveolar crest or harvesting bone fragments
• POWER LEVEL [SURG] 80%
• TiN coating
• Edge spatula tip
• Double-edged scraper 
				
	For flattening the alveolar crest or harvesting bone fragments.
For removal of diseased granulation tissues from extraction sites.
• TiN coating
• Rounded edge spatula tip
• Single-edged scraper

Ostroplasties
				
	For chin bone harvests, notably for the mental foramen and mandibular ramus. For general bone surgery.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Five teeth ; 0.6 mm thick
				
	For chin bone harvests, notably for the mental foramen and mandibular ramus. For general bone surgery. 
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Five teeth ; 0.6 mm thick
				
	For chin bone harvests, notably for the mental foramen and mandibular ramus. For general bone surgery. For use in deeper regions requiring longer tips.
• POWER LEVEL SURG 80%
• TiN coating
• Dots mark 3, 6, 9, 12 and 15 mm from tip end
• Five teeth ; 0.6 mm thick
				
	For excisions in areas with inclines or projections or which are otherwise hard to access with SG1 and other regular tips.
• POWER LEVEL [SURG] 80%
• TiN coating
• Right curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	For excisions in areas with inclines or projections or which are otherwise hard to access with SG1 and other regular tips. 
• POWER LEVEL [SURG] 80%
• TiN coating
• Left curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	For clinical cases where movement is restricted around the end of the tip.
• POWER LEVEL [SURG] 150%
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Three teeth ; 0.6 mm thick
				
	For clinical cases where movement is restricted around the end of the tip.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Three teeth ; 0.6 mm thick
				
	For clinical cases where movement is restricted around the end of the tip.
For use in deeper regions requiring longer tips.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6, 9, 12 and 15 mm from tip end
• Three teeth ; 0.6 mm thick
				
	For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• 90 degree right curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 150%
• HIGH POWER
• TiN coating
• 90 degree left curved tip*
• Three teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view
				
	For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 80%
• TiN coating
• 90 degree right curved tip*
• Five teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	For harvesting bone from the mandibular ramus.
• POWER LEVEL [SURG] 80%
• TiN coating
• 90 degree left curved tip*
• Five teeth ; 0.6 mm thick
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	For excisions in areas with inclines or projections or which are otherwise hard to access with SG1 and other regular tips.
For cutting curved surfaces.
• POWER LEVEL [SURG] 80%
• TiN coating
• Dot mark 3 mm from tip end
• Five teeth ; 0.8 mm thick
				
	For regions that are hard to access with regular tips, notably the posterior mandible or curved areas.
For narrow cutting to reduce bone loss. Also suitable for corticotomies.
• POWER LEVEL [SURG] 50%
• TiN coating
• Sharp edge
• 0.5 mm thick
				
	For regions that are hard to access with regular tips, notably the posterior mandible or curved areas.
For removing tori on the posterior mandible or mandibular lingual surface. 
• POWER LEVEL [SURG] 80%
• TiN coating
• Dots mark 3, 6 and 9 mm from tip end
• Three teeth ; 0.6 mm thick

Unilateral anterior mandibular sampling

Excision of bone torus

Anterior mandibylar harvesting

Mandibular harvesting at approach stage

The cutting part is bone torus
				
	Ruptures the periodontal ligament to streamline suture removal. Also effective in extracting ankylosed teeth.
• POWER LEVEL [SURG] 80%
• TiN coating
• 0.7 mm thick
				
	Ruptures the periodontal ligament to streamline suture removal. Also effective in extracting ankylosed teeth.
• POWER LEVEL [SURG] 50%
• TiN coating
• Right angled tip*
• 0.7 mm thick
* The direction of the tip’s angle is defined by the tip’s anterior view.
				
	Ruptures the periodontal ligament to streamline suture removal. Also effective in extracting ankylosed teeth.
• POWER LEVEL [SURG] 50%
• TiN coating
• Left angled tip*
• 0.7 mm thick
* The direction of the tip’s angle is defined by the tip’s anterior view.

Extraction
				
	Elevating the sinus membrane with internal irrigation approaching from alveolar crest.
• POWER LEVEL [SURG] 50%
• INTERNAL IRRIGATION
				
	For procedures such as osteotomy ofmaxillary sinus approaching from the alveolar crest and implant preparation site adjustments.
• POWER LEVEL [SURG] 80%
• INTERNAL IRRIGATION
• Diamond coating
				
	For expanding and forming implant preparation site when approaching from the alveolar crest.
• POWER LEVEL [SURG] 50%
• INTERNAL IRRIGATION
• Diamond coating
				
	Elevating the sinus membrane with internal irrigation approaching from alveolar crest.
• POWER LEVEL [SURG] 50%
• INTERNAL IRRIGATION
				
	For procedures such as osteotomy ofmaxillary sinus approaching from the alveolar crest and implant preparation site adjustments.
• POWER LEVEL [SURG] 80%
• INTERNAL IRRIGATION
• Diamond coating
				
	For expanding and forming implant preparation site when approaching from the alveolar crest.
• POWER LEVEL [SURG] 80%
• INTERNAL IRRIGATION
• Diamond coating
				
	Elevating the sinus membrane with internal irrigation approaching from alveolar crest.
• POWER LEVEL [SURG] 50%
• INTERNAL IRRIGATION
				
	For procedures such as osteotomy ofmaxillary sinus approaching from the alveolar crest and implant preparation site adjustments.
• POWER LEVEL [SURG] 80% 
• INTERNAL IRRIGATION
• Diamond coating
				
	For preparation of implant sites, adding starting points, and other steps.
• POWER LEVEL [SURG] 50%
• Diamond coating
• Tip-end diameter ; 0.7 mm
• Markings every 5 mm and 10 mm from tip end
				
	For preparation of implant sites, adding starting points, and other steps.
• POWER LEVEL [SURG] 50%
• Diamond coating
• Tip-end diameter ; 1.3 mm
• Markings every 5 mm and 10 mm from tip end
				
	For preparation of implant sites, flattening bone surfaces, and other steps.
• POWER LEVEL [SURG] 50%
• Diamond coating
• Tip-end diameter ; 0.9 mm
• Markings every 5 mm, 10 mm and 12 mm from tip end
				
	For preparation of implant sites, flattening bone surfaces, and other steps. 
• POWER LEVEL [SURG] 50%
• Diamond coating
• Tip-end diameter ; 1.3 mm
• Marking every 5 mm, 10 mm and 12 mm from tip end
				
	For expanding and forming implant preparation site when approaching from the alveolar crest.
• POWER LEVEL [SURG] 50%
• Diamond coating
• Diameter ; 2.0 mm
• Markings every 5 mm and 10 mm from tip end
				
	For expanding and forming implant preparation site when approaching from the alveolar crest.
• POWER LEVEL [SURG] 50%
• Diamond coating
• Diameter ; 2.6 mm
• Markings every 5 mm and 10 mm from tip end

Conical preparations for implant osteotomies

Implant preparation
				
	For bone fenestration and bone formations.
• POWER LEVEL [SURG] 80%
• Diamond coating
				
	For bone fenestration and bone formations.
• POWER LEVEL [SURG] 50% 
• Diamond coating

Avulsion of wisdom teeth and impacted teeth

Sinus graft
				
	For detachment and elevation of the maxillary sinus membrane.
• POWER LEVEL [SURG] 50%
• Flat circular convex elevator
• Angled at 90°
				
	For detachment and elevation of the maxillary sinus membrane.
• POWER LEVEL [SURG] 50%
• Flat circular convex elevator
• Angled at 135°
				
	For detachment and elevation of the maxillary sinus membrane.
• POWER LEVEL [SURG] 50%
• Cone compressor

Sinus membrane

Sinus graft
				
	Removal of supra gingival tartar, tartar narrow interdental space, marginal gingival calculus.
• POWER LEVEL [SURG] 50%
				
	Removal of gingival biofilm.
• POWER LEVEL [PERIO] 100%
				
	Removal of gingival biofilm.
Removal of Biofilm furcation area. 
• POWER LEVEL [PERIO] 100%
• Right curved type*
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	Removal of gingival biofilm.
Removal of Biofilm furcation area.
• POWER LEVEL [PERIO] 100%
• Left curved type*
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	• POWER LEVEL [PERIO] 100%
• Includes E-Tip replacement wrench
• Plastic Tip is not included
				
	For the maintenance of prostheses and implants. Produced from special material to allow safe debridement without causing damage to metals and implants.
• Pack of 3
• V10-S holder is not included
				
	Double bent tips. This tip is extra long to easily access difficult to reach areas and to avoid interference with neighbouring teeth or contours. 
• Pack of 3
• Right curved type*
• V10-S holder is not included
• V-P11R/L, V-P12 can be used only for VarioSurg 3
* The direction of the tip’s curve is defined by the tip’s anterior view
				
	Double bent tips. This tip is extra long to easily access difficult to reach areas and to avoid interference with neighbouring teeth or contours. 
• Pack of 3
• Left curved type*
• V10-S holder is not included
• V-P11R/L, V-P12 can be used only for VarioSurg 3
* The direction of the tip’s curve is defined by the tip’s anterior view.
				
	A longer version of the popular V-P10 tip.
• Pack of 3
• V10-S holder is not included
• V-P11R/L, V-P12 can be used only for VarioSurg 3
				
	• POWER LEVEL [ENDO] 50%
• Diamond coating
• For posterior teeth (right angled*)
* The direction of the tip’s angle is defined by the tip’s anterior view.
				
	• POWER LEVEL [ENDO] 50%
• Diamond coating
• For posterior teeth (left angled*)
* The direction of the tip’s angle is defined by the tip’s anterior view.
				
	• POWER LEVEL [ENDO] 50%
• Diamond coating
• For anterior and posterior teeth (70°)
				
	• POWER LEVEL [ENDO] 50%
• Diamond coating
• For anterior teeth (90°)
				
	SG1, SG3, SG5, SG6D, SG7D, SG11 / Tip holder
				
	BONE SURGERY / SINUS LIFT / SCRAPER / SINUS MEMBRANE DETACHMENT
Contents
• H-SG1, SG3, SG5, SG6D, SG7D, SG11
• Tip holder
				
	BONE SURGERY
Contents
• SG1, SG2R, SG4, SG2L, SG6D
• Tip holder
				
	ENDODONTICS
Contents
• G1-S, E30RD-S, E30LD-S, E31D-S, E32D-S
• Tip holder
				
	IMPLANT PREPARATION
Contents
• SG15A, SG15B, SG16A, SG16B
• Tip holder
				
	SINUS LIFT
Contents
• SG1, SG3, SG6D, SG9, SG10, SG11
• Tip holder
				
	SOCKET LIFT(CRESTAL APPROACH)
Contents
• SCL1D, SCL2D, SCL1
• VS Tip Wrench
• Tip holder
• Manual
				
	SOCKET LIFT(CRESTAL APPROACH)
Contents
• SCL2D, SCL3D, SCL4D, SCL3
• VS Tip Wrench
• Tip holder